Model |
2kVA(L) |
2kVA(H) |
3kVA(L) |
3kVA(H) |
4kVA(H) |
|
Capacity |
2kVA / 2kW | 2kVA / 2kW | 3kVA / 3kW | 3kVA / 3kW | 4kVA / 4kW | |
Input |
||||||
| Nominal Voltage/ Low-High / Range | (L) 120VAC – (H) 208 /220 /230 / 240 VAC / +28% / -15% @ full load | |||||
| Frequency Range | 46Hz ~ 54 Hz @ 50Hz system, 56Hz ~ 64 Hz @ 60Hz system | |||||
| Phase | 1 Phase with Neutral | |||||
| Power Factor | ≧ 0.99 at 100% Load | |||||
Output |
||||||
| Phase | 1 Phase with Neutral | |||||
| Output Voltage / Low- High | (L) 104/110/115/120, (H) 208 /220 / 230 / 240 | |||||
| AC Voltage Regulation | ± 1% (Normal) | |||||
| Frequency Range (Sync Range) | 46Hz ~ 54 Hz @ 50Hz system, 56Hz ~ 64 Hz @ 60Hz system, (Batt Mode) +/- 0.1% Hz | |||||
| Overload | AC Mode/ | 100%~110%: 1 hour; 110%~130%: 1min; >130% : 1sec | ||||
| Battery Mode | 100%~110%: 30sec; 110%~130%: 10sec; >130% : 1sec | |||||
| Current Crest Ratio | 3:1 max | |||||
| Voltage THD | ≦ 2 % @ 100% Linear Load; ≦ 4 % @ 100% Non-linear Load (PF≥0.8) | |||||
| Step Load Response | +/- 4% 50% step load, +/-6% 100% step load, Return +/-3% of nominal (11 cycles) | |||||
| Common Mode Noise | < 0.5 VRMS | |||||
| Normal Mode Noise | < 10% V | |||||
Efficiency |
||||||
| AC Mode | 90% | |||||
| Battery Mode | 88% | |||||
| ECO Mode | 97% | |||||
Battery |
||||||
| Voltage (VDC) | 240, Nominal, 270 Float | |||||
| Battery Backup Time Full Load (Internal) | 2kVA = 25 min batt backup, 3kVA = 15 min batt backup, 4kVA = 11 min batt backup at @ 100% full load/td> | |||||
| Quantity | 20 | |||||
| Recharge Time | 7 hours to 90% | |||||
Physical |
||||||
| Standard Model | Dimension, W x D x H (In.) | 9.8” x 28.2” x 32.5” | 9.8” x 28.2” x 32.5” | 9.8” x 28.2” x 32.5” | ||
| Net Weight (lbs) | 266 lbs | |||||
Bypass |
||||||
| Input Voltage | 110 ~ 276 VAC | |||||
| Output Voltage | 110 ~ 276 VAC | |||||
| Transformer Voltage Regulation | +/- 3% | |||||
| Overload Conditions | Continuous below 130%, 1 minute at 130%, 1 cycle at 1000% | |||||
Environment |
||||||
| Operation Temperature | 0 ~ 40°C (the battery life will down when > 25°C) | |||||
| Operation Humidity | <95 % and non-condensing | |||||
| Operation Altitude | 2000 ft. | |||||
| Heat Dissipation (BTU/Hr) | 1264 | 1686 | ||||
| Acoustic Noise Level (Front of Unit) |
55-60dB @ 1 Meter | 60dB @ 1 Meter | ||||
Management |
||||||
| Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC | |||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||
| MODBUS Card | Power Management with MODBUS communication | |||||
Agencies |
||||||
| RoHS | All units are RoHS compliant | |||||
| Safety Agencies | UL1778 5th Edition, CSA22.2 No.107.3, IEC 62040-2:2018 | |||||
| EMC | FCC Part 15J, Class A, EN 55022 Class A / CISPR 22, IEC 61000-3-2, IEC 61000-4-2, Electrostatic Discharge, IEC61000-4-3 Level 3 Radiated Electromagnetic Filed immunity. (Additional EMC Agencies listed in User’s Manual). | |||||
360 Power Quality Titanium Series Online UPS 2-4 kVA
The Titanium Series UPS from 360 Power Quality integrates digital signal processing (DSP) technology and an internal isolation transformer to safeguard equipment against power anomalies and ensure consistent, reliable power to the connected load. Optional EBMs, external maintenance bypass and customized back panels make the Titanium Series ideal for a variety of applications, including small data centers, medical labs and light industrial facilities.
Rating: 3000-10,000 VA Single-Phase UPS
Voltage: 208 /220 /230 / 240 Vac
Configuration: Tower
| Weight | 266 lbs |
|---|---|
| Dimensions | 9.8 × 28.2 × 32.5 in |
| Manufacturer | |
| Phase | |
| Power Rating kVA | |
| Configuration | |
| Model | 2kVA(L), 2kVA(H), 3kVA(L), 3kVA(H), 4kVA(H) |
Additional information
| Weight | 266 lbs |
|---|---|
| Dimensions | 9.8 × 28.2 × 32.5 in |
| Manufacturer | |
| Phase | |
| Power Rating kVA | |
| Configuration | |
| Model | 2kVA(L), 2kVA(H), 3kVA(L), 3kVA(H), 4kVA(H) |