360 Power Quality Titanium Series Online UPS 5.2-10kVA

The Titanium Series UPS from 360 Power Quality integrates digital signal processing (DSP) technology and an internal isolation transformer to safeguard equipment against power anomalies and ensure consistent, reliable power to the connected load. Optional EBMs, external maintenance bypass and customized back panels make the Titanium Series ideal for a variety of applications, including small data centers, medical labs and light industrial facilities. 

 

Rating: 3000-10,000 VA Single-Phase UPS

Voltage: 208 /220 /230 / 240 Vac

Configuration: Tower

Manufacturer

Phase

Power Rating kVA

Configuration

Model

5.2kVA(H), 6kVA(H), 8kVA(H), 10kVA(H)

Description

 

Model

5.2kVA(H)

6kVA(H)

8kVA(L)

10kVA(H)

Capacity

5.2kVA / 5.2kW 6kVA / 6kW 8kVA / 8kW 10kVA / 10kW

Input

Nominal Voltage/ Range 208 /220 /230 / 240 VAC / +28% / -15% @ full load
Frequency Range 46Hz ~ 54 Hz @ 50Hz system, 56Hz ~ 64 Hz @ 60Hz system
Phase 1 Phase with Neutral
Power Factor ≧ 0.99 at 100% Load

Output

Phase 1 Phase with Neutral
Output Voltage / Low- High 104 /110 / 115 / 120 / 208 /220 / 230 / 240
AC Voltage Regulation ± 1% (Normal)
Frequency Range (Sync Range) 46Hz ~ 54 Hz @ 50Hz system, 56Hz ~ 64 Hz @ 60Hz system, (Batt Mode) +/- 0.1% Hz
Overload AC Mode/ 100%~110%: 1 hour; 110%~130%: 1min; >130% : 1sec
Battery Mode 100%~110%: 30sec; 110%~130%: 10sec; >130% : 1sec
Current Crest Ratio 3:1 max
Voltage THD ≦ 2 % @ 100% Linear Load; ≦ 4 % @ 100% Non-linear Load (PF≥0.8)
Step Load Response +/- 4% 50% step load, +/-6% 100% step load, Return +/-3% of nominal (11 cycles)
Common Mode Noise < 0.5 VRMS
Normal Mode Noise < 10% V

Efficiency

AC Mode 90%
Battery Mode 88%
ECO Mode 97%

Battery

Voltage (VDC) 240, Nominal, 270 Float
Battery Backup Time Full Load (Internal) 2kVA = 25 min batt backup, 3kVA = 15 min batt backup, 4kVA = 11 min batt backup at @ 100% full load/td>
Quantity 20
Recharge Time 7 hours to 90%

Physical

Standard Model Dimension, W x D x H (In.) 9.8” x 28.2” x 32.5” 9.8” x 28.2” x 32.5” 9.8” x 28.2” x 32.5”
Net Weight (lbs) 266 lbs 301 lbs

Bypass

Input Voltage 110 ~ 276 VAC
Output Voltage 110 ~ 276 VAC
Transformer Voltage Regulation +/- 3%
Overload Conditions Continuous below 130%, 1 minute at 130%, 1 cycle at 1000%

Environment

Operation Temperature 0 ~ 40°C (the battery life will down when > 25°C)
Operation Humidity <95 % and non-condensing
Operation Altitude 2000 ft.
Heat Dissipation (BTU/Hr) 1970 2530 3372 4215
Acoustic Noise Level
(Front of Unit)
55-60dB @ 1 Meter 60dB @ 1 Meter

Management

Smart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
MODBUS Card Power Management with MODBUS communication

Agencies

RoHS All units are RoHS compliant
Safety Agencies UL1778 5th Edition, CSA22.2 No.107.3, IEC 62040-2:2018
EMC FCC Part 15J, Class A, EN 55022 Class A / CISPR 22, IEC 61000-3-2, IEC 61000-4-2, Electrostatic Discharge, IEC61000-4-3 Level 3 Radiated Electromagnetic Filed immunity. (Additional EMC Agencies listed in User’s Manual).